• Users Online: 2125
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2022  |  Volume : 71  |  Issue : 3  |  Page : 186-190

Dimensional accuracy of medical models of the skull produced by three-dimensional printing technology by advanced morphometric analysis


1 Department of Anatomy, SRM Medical College Hospital and Research Center, Kattankulathur, Tamil Nadu, India
2 Department of Translational Medicine, SRM Medical College Hospital and Research Center, Kattankulathur, Tamil Nadu, India
3 Department of Basic Medical Science; Department of Medical Education, College of Dentistry, Majmaah University, Al Zulfi, Riyadh, Saudi Arabia

Correspondence Address:
Dr. Sharmila Aristotle
Department of Anatomy, SRM Medical College Hospital and Research Center, Kattankulathur - 603 203, Tamil Nadu
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jasi.jasi_202_21

Rights and Permissions

Introduction: Three-dimensional (3D) printing creates a design of an object using software, and the process involves by converting the digital files with a 3D data using the computer-aided design into a physical model. The aim of the study was to investigate the accuracy of human printed 3D skull models from computed tomography (CT) scan data via a desktop 3D printer, which uses fused deposition modeling (FDM) technology. Material and Methods: Human anatomical cadaver skulls were CT scanned in 128-slice CT scanner with a slice thickness of 0.625 mm. The obtained digital imaging and communications in medicine files were converted to 3D standard tessellation language (STL) format by using MIMICS v10.0 software (Materialise, Leuven, Belgium) program. The 3D skull model was printed using a Creatbot DX desktop 3D FDM printer. The skull model was fabricated using polylactic acid filament with the nozzle diameter of 0.4 mm and the resolution of the machine was maintained at 0.05 mm. The accuracy was estimated by comparing the morphometric parameters measured in the 3D-printed skull with that of cadaver skull and with CT images to ensure high accuracy of the printed skull. Fourteen morphometric parameters were measured in base and cranial fossa of the skull based on its surgical importance. Results: Analysis of measurements by inferential statistical analysis of variance for all three groups showed that the 3D skull models were highly accurate. Reliability was established by interobserver correlation for measurements on cadaver skull and the 3D skulls. Dimensional error was calculated, which showed that the errors between three groups were minimal and the skulls were highly reproducible. Discussion and Conclusion: The current research concludes that a 3D desktop printer using FDM technology can be used to obtain accurate and reliable anatomical models with negligible dimensional error.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed158    
    Printed2    
    Emailed0    
    PDF Downloaded25    
    Comments [Add]    

Recommend this journal